01
Coral Board System
02
Passive Fire Protection Systems for Buildings
03
Prefabricated Component System
04
MIC Prefabricated Component System
Partition wall (corridor wall/mountain wall/end wall)
Partition wall (corridor wall/mountain wall/end wall)
S series corridor partition wall
S series corridor partition wall
A-series corridor partition wall/mountain wall/end wall
A-series corridor partition wall/mountain wall/end wall

PRODUCT

PERFORMANCE

Fire safety

The fire protection level reaches A1 non combustible level, and has passed national authoritative testing to meet the strict fire protection requirements of various types of buildings;

安必安新国标GB木质防火一体门芯

High strength load-bearing capacity

A single self tapping nail can vertically hang heavy objects up to 45kg;

安必安新国标GB木质防火一体门芯

Impact resistance

Adopting multi-element magnesium based gel foaming technology, it can withstand 50 impacts of 30kg sandbags, with a sturdy and durable structure;

安必安新国标GB木质防火一体门芯

Environmental Protection and Health

The substrate is independently developed Ankong board, without formaldehyde addition, reaching ENF formaldehyde free level and smoke toxicity AQ1 level;

安必安新国标GB木质防火一体门芯

Efficient installation

Adopting dry operation and modular design, on-site assembly is fast and convenient, greatly reducing the construction period;

安必安新国标GB木质防火一体门芯

Beautiful finish

SPC veneer is wear-resistant and scratch resistant, providing a variety of color options to meet the decorative style needs of different spaces.

安必安新国标GB木质防火一体门芯

PRODUCT

SPECIFICATION

American standard UL frame structure MiC partition wall


scope of applicationProduct namePipeline configurationProduct descriptionSoundproofFire resistance limitWeight (kg/㎡)FinishingStandard size(H*W*T) mmIllustration
Corridor wall110S UL split partition wallBuilt-in15mm safety panel * 2+ An Kuang 1200 keel * 2+ SPCFinishing board * 244dB+2H41SPCFinishing board (Wood grain/skin texture/cloth texture))2400-2950*600*110

Partition wall(Corridor wall/Gables/end walls)

150S UL split partition wallBuilt-in46dB+432400-2950*600*150
110A UL split partition wallBuilt-in15mm安旷面板*2+ 安旷1200龙骨*2+ 30mm厚120k岩棉*2+ SPCFinishing板*247dB+482400-2950*600*110

Partition wall(Corridor wall/Gables/end walls)

150A UL split partition wallBuilt-in50dB+502400-2950*600*150
Gables/end walls110A UL split partition wallBuilt-in15mm Ankong panel * 2+Ankong 1200 keel * 2+30mm thick 120k rock wool * 2+SPC Finishing board * 247dB+2H48SPCFinishing board (Wood grain/skin texture/cloth texture))2400-2950*600*110

Partition wall(Corridor wall/Gables/end walls)


European standard EN frame structure MiC partition wall


Scope of applicationProduct namePipeline configurationProduct descriptionSoundproofFire resistance limit

Weight

 (kg/㎡)

Finishing

Standard size(H*W*T)

 mm

Illustration
Corridor wall90S Split partition wallExternal15mm Ankong panel * 2+Ankong 1200 keel * 2+SPC Finishing board * 242dB+ 1H36SPCFinishing board (Wood grain/skin texture/cloth texture))2400-2950*950*90Partition wall(Corridor wall/Gables/end walls)
110S Split partition wallBuilt-in44dB+372400-2950*950*110
150S/1H Split partition wallBuilt-in46dB+392400-2950*950*150
90A Split partition wallExternal15mm Ankong panel * 2+Ankong 1200 keel * 2+30mm thick 120k rock wool * 2+SPC Finishing board * 245dB+432400-2950*950*90Partition wall(Corridor wall/Gables/end walls)
110A Split partition wallBuilt-in47dB+442400-2950*950*110
150A/1H Split partition wallBuilt-in50dB+462400-2950*950*150
100A Split partition wallExternal20mm Ankong panel * 2+Ankong 1200 keel * 2+30mm thick 120k rock wool * 2+SPC Finishing board * 248dB+2H522400-2950*950*100Partition wall(Corridor wall/Gables/end walls)
120A Split partition wallBuilt-in50dB+532400-2950*950*120
150A/2H Split partition wallBuilt-in53dB+552400-2950*950*150
Gables/end walls90A Split partition wallExternal15mm Ankong panel * 2+Ankong 1200 keel * 2+30mm thick 120k rock wool * 2+SPC Finishing board * 245dB+ 1H43SPCFinishing board (Wood grain/skin texture/cloth texture))2400-2950*950*90Partition wall(Corridor wall/Gables/end walls)
110A Split partition wallBuilt-in47dB+442400-2950*950*110
95A Split partition wallExternal20mm Ankong panel * 2+Ankong 1200 keel * 2+30mm thick 120k rock wool * 2+SPC Finishing board * 247dB+2H482400-2950*950*95Partition wall(Corridor wall/Gables/end walls)
115A Split partition wallBuilt-in49dB+492400-2950*950*115


National standard GB frame structure MiC partition wall


Scope of applicationProduct namePipeline configurationProduct descriptionSoundproofFire resistance limitWeight (kg/㎡)FinishingStandard size(H*W*T) mmIllustration
Corridor wall110S Split partition wallBuilt-in15mm Ankong panel * 2+Ankong 1200 keel * 2+SPCFinishing board * 244dB+2H37SPCFinishing board (Wood grain/skin texture/cloth texture)2400-2950*600*110Partition wall(Corridor wall/Gables/end walls)
150S Split partition wallBuilt-in46dB+392400-2950*600*150
110A Split partition wallBuilt-in15mm Ankong panel * 2+Ankong 1200 keel * 2+30mm thick 120k rock wool * 2+SPCFinishing board * 247dB+442400-2950*600*110Partition wall(Corridor wall/Gables/end walls)
150A Split partition wallBuilt-in50dB+462400-2950*600*150
Gables/end walls110A Split partition wallBuilt-in15mm Ankong panel * 2+Ankong 1200 keel * 2+30mm thick 120k rock wool * 2+SPC Finishing board * 247dB+2H44SPCFinishing board (Wood grain/skin texture/cloth texture)2400-2950*600*110Partition wall(Corridor wall/Gables/end walls)

INSTALLATION

INSTRUCTIONS

Initial installation
Initial installation
Installation at vertical connections
Installation at vertical connections
Final installation
Final installation
Top installation
Top installation
Bottom installation
Bottom installation
End walls and windows
End walls and windows

INSTALLATION

CONDITION

Basic conditions

1. The construction ground should be flat and sturdy, with a horizontal deviation of no more than 3mm/m, to ensure that the partition wall is installed vertically and stably;

2. The construction area needs to be clean and dry, with no accumulated water, oil stains or other pollutants;

3. Reserve sufficient operating space (recommended ≥ 800mm) for modular assembly and adjustment.


Environmental parameters

The construction environment temperature should be maintained within the range of 5 ℃ -40 ℃ to avoid extreme high or low temperature operations.


Storage and Handling

1. When storing materials, they should be protected from rain and direct sunlight, and the stacking height should not exceed 1.5m to prevent deformation;

2. Handle with care during transportation to avoid scratches on the decorative layer (SPC) or damage to the edges and corners of the board.


Tip: The entire construction process adopts dry operation, without the need for wet operation, reducing on-site pollution and improving efficiency.